Starting
Now turn the key further to the start
position.
Release the key as soon as the engine
fires (the key will return to the oN posi-
tion) and throttle back.
Leave the key in this position while the
engine is running.
Check that the indicator lights for oil pres-
sure and alternator are off. Cooling water
should now flow out of the exhaust; if this
is not the case, stop the engine immedi-
ately. Before submitting the engine to full
load it should be brought up to operating
temperature as quickly as possible by
running at 3/4 of maximum revs. Never
turn the main switch off while the engine
is running.
The instrument panel is provided with the
following instruments (Depending of the
type of panel, see page 10).
Use
Starting
WarNiNg
Release the key if the engine does
not fire within 10 seconds. Wait until
the starter motor has stopped running
completely before turning the key to
the startposition again. Never allow
the starter motor to run for more than
30 seconds consecutively.
VD00109
VD00110
WarNiNg
Never turn the key to the startposi-
tion while the engine is running.
Doing so will damage the starter
motor.