Fault finding table
7 Troubleshooting
1 Engine will not crank
Possible fault Remedy
Control lever not in neutral. Put operating lever in neutral
The emergency stop knob is
pushed in (ECU Box) .
Pull the emergency stop knob
out.
Faulty or discharged battery
(too low voltage ) .
Check / recharge battery and
check engine alternator and/or
battery charger.
Fuse blown. Replace.
Loose or corroded connections
in starting circuit.
Clean and tighten connections.
Faulty starter-switch or faulty
starter-relay.
Check / replace.
Faulty starter-motor or pinion
does not engage.
Check / replace starter-motor.
Starter relay is not engaged due
to a voltage too low; caused by
a very long intermediate cable
from engine to control panel.
Install an auxiliary starter relay
Seized components. Repair.
1 Engine will not crank
Possible fault Remedy
Wrong engine electric mass
connection.
Repair.
Water in the cylinder . Check / Repair .