41 Impeller inspection
• Inspecttheimpellerfordamage.
• Replacetheimpellerifnecessary.
42 Re-install the impeller
• Theimpellershould belubricatedwith
glycerin or a non-petroleum based lubri-
cant such as a silicone spray before fit-
ting it into the impeller housing.
• Fittheimpellertothepumpshaft.(ifan
existing impeller is re-used, install it in
the same position as removed).
The direction of rotation of the impeller
is anti-clockwise.
43 Replacing the pump cover
• Alwaysuseanewgasketwhenreplac-
ing the cover.
• Checkthewaterfilterandopenthesea
cock.
Raw water pump inspection
Every 800 operating hours.
4 Maintenance
VD00127 VD00004 VD00697
iMpeller, art.cOde: StM9456 GaSket, art.cOde: StM8235